Product Set

LeveLine

Our Leveline series offers customers absolute and vented sensors for groundwater and surface water monitoring.

When you need a reliable water level logger for any type of water monitoring application, our industry leading LeveLine absolute range is the perfect solution for you. The Leveline has an impressive specification as standard at market leading prices.

  • Produced from Titanium
  • 500,000 Data point memory.
  • Ten-year battery life.
  • Five-year warranty.

Ruggedness As Standard

Having strong and dependable equipment is essential when it comes to monitoring water levels effectively and accurately, and this is where the LeveLine range can help. Since each water level logger has been built with reliability and ruggedness in mind to meet the demanding needs of a wide range of monitoring applications, you can depend on its high quality to perform to the required standards. The strong titanium construction ensures that these loggers and sensors can withstand use in even challenging environments.

Low Maintenance

Each Leveline is lifetime factory calibrated and requires virtually no maintenance during it’s entire life. With our recently enhanced warranty offering you can have the extra confidence over our competitors. Aquaread supports all of it’s customers to the highest possible level, we offer training courses on the Leveline range to our customer to help them get the best from them.

Highly Accurate

Accuracy is essential during any water level monitoring application, no matter how challenging the environment. The inbuilt pressure sensor used in the LeveLine logger range has been designed to measure even the smallest changes to the surface or groundwater levels extremely accurately and recording the water temperature is also incredibly simple and efficient for maximum ease and convenience for the user.

The LeveLine range now also includes our impressive LeveLine CTD device which is able to record not only water temperature and level but also its conductivity and salinity. This opens up further application suitability to our customers such as tracer testing, saltwater intrusion or routine chemistry measurements along with level and temperature.

LeveLine Baro

LeveLine-Baro

Air pressure logger for use with absolute setup.

Read More
LeveLine logger

LeveLine

Self contained titanium water level and temperature logger.

Read More
LeveLine

LeveLine-Mini

Titanium SDI-12 level and temperature sensor.

Read More
LeveLine

LeveLine-Mini CTD

Adds conductivity and salinity measurements.

Read More
Aquasonde-2000 battery compartment

LeveLine-CTD

The titanium LeveLine-CTD offers water level, temperature, conductivity and salinity logging.

LeveLine-EWS

LeveLine-EWS

Early flood warning system

Read More
LeveLine

Quick Deploy Key

Initiate logging and check memory and battery levels.

Read More
LeveLine

GPS LeveLine Meter

Handheld logging and setup device.

Read More

Water Level Specifications

GENERAL

LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Temperature ranges Operational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F)
Operational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F)
Operational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F)
Operational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F)
Operational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F)
Diameter 22.2mm (0.875 in) 22.2mm (0.875 in) 22.2mm (0.875 in) 22mm 22mm
Length 186mm (7.32 in) 186mm (7.32 in) 87mm (3.43 in) 260mm 146mm
Weight 150g (5.3oz) 160g (5.6oz) 120g (4.2oz) 250g 210g
Materials Titanium body, Delrin nose cone Stainless Steel body, Delrin nose cone Stainless Steel body, Delrin nose cone Titanium body, Delrin nose cone Titanium body, Delrin nose cone
Output options Modbus/RS485, SDI-12, Aquaread proprietary Modbus/RS485, SDI-12, Aquaread proprietary Modbus/RS485, SDI-12, Aquaread proprietary Modbus/RS485, SDI-12, Aquaread proprietary Modbus/RS485, SDI-12, Aquaread proprietary
Battery type & life 3.6V lithium; up to 10 years (see note 1) 3.6V lithium; up to 10 years (see note 1) N/A 3.6V lithium; up to 10 years (see note 1) N/A
External power 6 – 30 VDC 6 – 30 VDC 6 – 30 VDC 6 – 24 VDC 6 – 24 VDC

MEMORY

LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Size 8.0 MB 2.0 MB N/A 8.0 MB N/A
Data records 500,000 150,000 N/A 500,000 N/A
Log types Linear, Event & User-Selectable
Schedule with Future Start, Future Stop,
Deploy Start and Real Time View
Linear, Event & User-Selectable
Schedule with Future Start, Future Stop,
Deploy Start and Real Time View
N/A Linear, Event & User-Selectable Schedule with Future
Start, Future Stop, Deploy Start and Real Time View
N/A
Fastest logging rate & Modbus rate 10 per second 1 per minute (logging)
5 per second (Modbus)
10 per second (Modbus Rate) 1 per second 1 per second
Fastest SDI-12 output rate 1 per second 1 per second 1 per second 1 per second 1 per second
Real-time clock Accurate to 1 second/24-hr period (± 6 minutes/year) Accurate to 1 second/24-hr period (± 6 minutes/year) N/A Accurate to 1 second/24-hr period (± 6 minutes/year) N/A

SENSOR

LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Type / Material Piezoresistive; ceramic Piezoresistive; ceramic Piezoresistive; ceramic Piezoresistive; ceramic Piezoresistive; ceramic
Range (Absolute) 10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft) 0 to 16.7 psi; 0 to 1.15 bar 10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft) 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft) 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft)
Range (Gauge) 10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft) N/A N/A 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft) 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft)
Maximum pressure Max 2x range, Burst 2.5x range Max 2x range, Burst 2.5x range Max 2x range, Burst 2.5x range Max 2x range, Burst 2.5x range Max 2x range, Burst 2.5x range
Accuracy (FS) (see note 3) ±0.05% FS ±0.05% FS ±0.05% FS ±0.05% FS ±0.05% FS
Accuracy (FS) (See note 2) ±0.1% FS ±0.1% FS ±0.1% FS ±0.1% FS ±0.1% FS
Resolution 0.005% FS or 1mm whichever is greater 0.1mb 0.005% FS or 1mm whichever is greater 0.002% FS or 1mm whichever is greater 0.002% FS or 1mm whichever is greater
Units of measure Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm, m Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm, m Pressure: mbar (psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm and m available in LeveLink Pressure: mbar (psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm and m available in LeveLink

ELECTRICAL CONDUCTIVITY

LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Range N/A N/A N/A 0 – 200mS/cm (0 – 200,000µS/cm) 0 – 200mS/cm (0 – 200,000µS/cm)
Resolution N/A N/A N/A 1µS 1µS
Accuracy N/A N/A N/A ± 1% reading or ±1µS whichever is greater (see note 5) ± 1% reading or ±1µS whichever is greater (see note 5)

TEMPERATURE SENSOR

LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Range N/A N/A N/A 0 – 70 PSU / 0 – 70 ppt (g/Kg) 0 – 70 PSU / 0 – 70 ppt (g/Kg)
Resolution N/A N/A N/A 0.01PSU / 0.01 ppt 0.01PSU / 0.01 ppt
Accuracy N/A N/A N/A ±1% reading or ± 0.1 unit if greater ±1% reading or ± 0.1 unit if greater

WARRANTY

LEVELINE – (Abs & Gauge) LEVELINE – BARO LEVELINE- MINI LeveLine-CTD LeveLine-Mini-CTD
Standard N/A N/A N/A 2 years 2 years
Extended N/A N/A N/A Options Available Options Available

Notes: 1) Dependent on logging rate. 2) Across factory-calibrated pressure range at a constant temperature. 3) Across factory-calibrated pressure and temperature ranges. 4) Readings calculated from EC and temperature values. 5) At the calibration point at 25°C