AquaPlus – Portable, GPS AquaPlus Optical DO/EC system

The AquaPlus probe is a combined optical dissolved oxygen, electrical conductivity and temperature sensor. Thanks to the built in conductivity sensor, the AquaPlus is able to calculate and automatically compensate DO readings for changes in water salinity. It’s compact, robust and highly accurate. It also requires very little maintenance to keep it that way. The slim probe is used with its very own GPS DO meter, meaning the location of every datapoint you measure is also recorded.

The AquaPlus Gallery

A quick introduction to the AquaPlus

Request a Quote Rent a System System Specifications

The luminescence based method for measuring dissolved oxygen has the following advantages:

  • Very low maintenance
  • No electrolyte to replace
  • No flow of water is required to achieve a steady reading
  • Holds calibration longer

The AquaPlus probe is available as a complete package including the probe with built in 3m cable and our GPS DO Meter, all packed in a hard carry case with foam cut-outs to keep your equipment safe.

AquaPlus Mechanical Specification

Some of the AquaPlus’ features

Advanced Optical DO sensor

The optical sensor works on the principle of Dynamic Luminescence Quenching. A gas-permeable material known as a luminophore is excited with short bursts of blue light, which causes molecules in the luminophore to emit red photons.

By measuring the delay of the returned red photons with respect to the blue excitation, the level of dissolved oxygen present can be determined.
The optical method has various advantages over the historical galvanic method for measuring dissolved oxygen.

optical DO sensor

The bright red and blue LED’s of the optical DO sensor

The most important being that as no oxygen is consumed across a membrane, the sensor does not require a flow of liquid passing over it to achieve a stable reading. Other advantages include in frequent calibrations (every 3-6 months), and replaceable caps that last over 2 years.

Combined DO/EC/Temp sensor

The AquaPlus sensor houses the optical sensor module on the tip, a 4 ring stainless steel conductivity sensor and an embedded temperature sensor.

The inclusion of the EC sensor allows the unit to calculate the salinity and automatically compensate the % saturation reading for salinity effects.

DO Cap and the 4 ring EC sensor

Using the AquaPlus with the GPS DO meter means that the location of every reading you record is logged with every data set.This information can be utilised in OxiLink where you can export a Google file to display your measurements on a map.
Pin Point your data in Google Earth

Pin Point your data in Google Earth

Please Like & Share:

Comments are closed.

Aquaread® - Community Trade Mark Registration No. 011713815
Aquaread® - Australia Trade Mark Registration No. 1436803
LeveLine® - Community Trade Mark Registration No. 011713823
Aquaprobe® - UK Trade Mark Registration No. 00003000628
Aquameter® - UK Trade Mark Registration No. 00003000627
LoggerLink® - UK Trade Mark Registration No. 3081814
Leveline-CTD® - Community Trade Mark Registration No. 016187338

Download Aquaread's Terms & Conditions
Download Aquaread's Environmental Policy
Download Aquaread's Green Procurement Policy
Download Aquaread's Quality Policy

ISO certification for ISO 9001 and 14001